This design routine assists design engineers in choosing the most appropriate core material and size for a number of different current transformer (CT) topologies.
Namely, the following three CT styles are included:
- "Traditional" (often line frequency) Current Transformers
- "Traditional" Current Transformers fall into a general category known as instrument transformers. Their main purpose is to produce, from the primary current, a proportional secondary current that can easily be measured or used to control various circuits. The primary winding is connected in series with the source current to be measured, while the secondary winding is normally connected to a meter, relay, or a burden resistor to develop a low level voltage that is amplified for control purposes.
- Hall Effect Current Transformers - The characteristics of a Hall Effect generator make it suitable for detector elements in magnetometers, clamp-on DC-AC ammeters, transducers, magnetic field variation meters, and wattmeters.
In the specific case of current sensors, the Hall generator/sensor is placed within air gap of a magnetic core. The core is usually a toroid, and features a soft magnetic material (such as ferrite, Molypermalloy powder, or Kool
Mu®). An initial core size is chosen to support the central primary conductor, and a gap is estimated to accommodate not only the thickness of the Hall Sensor itself, but also to ensure that the correct flux field will be set up within the core material at the sensor's peak current to be detected.
- SMPS Current Transformers -
Current Transformers for SMPS designs are used to sense current levels within the control loop of the power supply. The current transformer in this scheme (usually made using a ferrite toroid) helps to track the current in the control circuit's feedback loop. This current is then used to determine how the future behavior of the SMPS will be modified. For instance, the duty cycle (for pulse width modulated systems) might be altered for future switching cycles.
Individual help topics are included for each CT style. Additionally, a reference section is included within the Online Help detailing sources of further information.
To download this software, right-click on the link link below, and
select "Save As" from the pop-up menu. You will need
software such as WinZip to un-zip and install the program. Get
WinZip® now.
This software runs under Windows 95/ 98SE/NT/2000. Some Windows 95 users may experience problems due to an old release of the operating software. Patches included in the ZIP files will fix some problems. If problems persist, try updating to the latest service pack,
or contact a MAGNETICS